How to fix EDI Failures

How to fix EDI Failures

1. Connect to the remote server FS-TRANZTEC and login
2. There should be an error message given for the failure, click "Copy the message to the clipboard"


3. Open SQL, sign in to fs-tmw3, click on "New Query" and paste the error message that was copied


4.  There should be a "query command" highlight that command, and click "Execute"


5. You should receive  similar message that the issue has been resolved. 



6. Go back to the remote server FS-TRANZTEC, and verfiy that it is running again. I should look similar to this 



7. If the error message from step 3 does not have a query command, then likely the file has failed multiple times, and cannot be transferred. This file needs to moved into the "MultipleFailures" folder to allow the server to run again. After the file has been moved, click "Ok" on the error message. The error message should look similar to this: 

"Exception Info: Object reference not set to an instance of an object.

Exception Stack Trace:    at EDI204Validation.EDIRoutines.LabelWithOrderNumberRefs(String sourceField, String EDIRefType, Boolean EDI204UpdateValidation, Boolean EDI204MaritimeValidation, List`1 sdt, SqlConnection TSSqlConn)
   at DX.frmMain.BuildInMemoryDXArchiveCache(String settingvalue, Boolean EDI204UpdateValidation, Boolean EDI204MaritimeValidation) in F:\NSuite-2020.4\DXRating\TMWDX\frmMain.vb:line 13570
   at DX.frmMain.ImportFlatFile(String FullPathFileWip) in F:\NSuite-2020.4\DXRating\TMWDX\frmMain.vb:line 11462

Additional Info:
MachineName: FS-TRANZTEC
TimeStamp: 8/31/2023 9:43:12 AM
FullName: Microsoft.Practices.EnterpriseLibrary.ExceptionHandling, Version=3.1.0.0, Culture=neutral, PublicKeyToken=null
AppDomainName: TMWDX.exe
ThreadIdentity: EDIADMIN
WindowsIdentity: FS\administrator
TMW Exception Management Version: 2020.4.1.139
Assembly Version Info: TMWDX, Version=2020.4.1.139, Culture=neutral, PublicKeyToken=null
File Version Info: 2020.4.1.139"




The file should have the date repeating multiple times, to show the times it tried to process.  "20230831"








*take a smoke break
    • Related Articles

    • AMS Silverlight error message

      If you're experiencing an an issue where IWS (Interactive Workstation) will not load due to a Microsoft Silverlight issue, use the following steps to resolve this issue: 1. Open Microsoft Edge and go to Settings 2. Go to Default browser 3. Under ...
    • Creating a new employee in TMT for TINA Edit

      1. Open and login to TMT (Transman) 2. Click on "Employees" in the 3. Fill out all required fields marked with " * ". For "Employee ID:" use the first four of letters of the last name, and the first for letters of the first name of the employee. ...
    • Building a Homepage for WFMs

      1. Create a new WFM form 2. Add a Radio box, label it "Please select which Form you are trying to access", and name it "choice" 3. Add a text box, label it URL, and name it url. Save your progress 4. Go to "Rules", create a new rule, select "Rule" ...